Picturesque suburban neighborhood with elegant homes, blooming trees, and a parked car on a sunny day.

Level 1 or 2 for a Rental?

Book This for a Building

By sending, you agree Ellery Chimney Contractors may contact you by call, automated text or email about your request. Consent isn't required to buy. Msg & data rates may apply; reply STOP to opt out. Privacy Policy

Dated Report Per Unit
Photos With Every Visit
Written Scope Before Repairs
Tenant Notice Wording Supplied
Priced Per Chimney
Building Summary Included
Dated Report Per Unit
Photos With Every Visit
Written Scope Before Repairs
Tenant Notice Wording Supplied
Priced Per Chimney
Building Summary Included
Row of brick chimneys with clay pots on terraced houses

The short answer for a building

Most fireplaces in a rental building need the Level 1 in most years, and a few need the Level 2 in any given year. The useful work is sorting them before the round, so you pay $380 only where the camera has a reason to go and $53 everywhere else.

The guidance behind chimney inspections, NFPA 211, describes three depths of inspection and ties each to a situation rather than a type of building. That makes the sorting a records job: what happened at each fireplace since it was last seen. For a San Dimas manager with a few buildings, the answer is usually sitting in the maintenance log already.

Where the $53 Level 1 fits

The Level 1 suits a fireplace whose use is steady: same fuel, same appliance, no tenant reports, nothing unusual since the last visit. It looks at everything reachable without opening the structure: the firebox and its lining, the damper, the hearth and trim clearances, the cap, crown and roof seal from above, and the chimney in the attic where a hatch allows.

On a stable building this is the yearly round. It gives every unit a dated page and catches the slow problems: a damper rusted shut, a crown starting to split, a cap lifted off in a wind, a tenant storing boxes too close to the opening.

Where the $380 Level 2 fits

The Level 2 adds a recorded camera run up the inside of the flue to the attic and roof checks. It is the level for a fireplace with a reason. For rentals, the reasons usually are:

  • A change of owner. You just bought the building, or you are selling it. The standard treats a transfer as grounds for the deeper check, and buyers expect it.
  • A tenant report. Smoke in the room, a loud rushing in the flue, a smell when it rains, flakes of black material in the firebox.
  • A change of appliance. A wood fireplace is getting a gas insert, a log set is going in, or an old insert is being swapped.
  • A shake or a strike. A quake strong enough to crack plaster, or lightning or a falling limb near the stack.
  • A Level 1 that could not settle it. A crack visible at the top of the flue, or a damper frame pulling away, where only the camera shows how far it runs.
  • A paperwork request. An insurer or lender asks for a record of the flues.

The rare third level

Level 3 means opening part of the structure, a wall panel or a section of brick, to see something hidden. On rentals it comes up after a chimney fire or a quake when the Level 2 shows damage running beyond the camera's view. It is never a first visit; it follows a Level 2 and is scoped in writing before anything is opened.

Sorting a building before the round

The sorting happens before we arrive, mostly from your own records:

  • list every fireplace by building and unit
  • mark any unit with a tenant report since the last round
  • mark any unit where the appliance changed or is about to
  • mark the whole building if it changed hands, or if a lender or insurer asked
  • everything unmarked goes on the Level 1 list

If a Level 1 turns up a reason on the day, we tell you on site and you decide whether that unit moves up. Nothing changes price without your say.

A common pattern on a mixed building: the units with gas fireplaces and no reports sit on the Level 1 list, the one wood unit where the tenant mentioned smoke goes to Level 2, and a vacant unit that is about to get a gas insert goes to Level 2 as well, so the camera record is in hand before the installer orders a liner.

What decides the level, and the next step

The level follows the reason, not the size of the unit or the fuel. A gas fireplace with a tenant smoke report gets the camera; a wood fireplace with a quiet year does not. Send the building list with any unit that had a report, a change or a sale flagged, and we return a written plan: which units at $53, which at $380, and the total.

Ask for a sorted inspection plan

What lands in the file

Both levels produce the same per-fireplace page: building, unit, date, type, findings and a status line. The Level 2 page adds stills from the camera run at the points that matter, such as a cracked tile, an open joint or a liner seam. When a unit later comes up in a claim or a sale, that page shows what the flue looked like on that date, not what someone remembers.

Over a few years the pages build a history for each fireplace. A unit that has sat at Level 1 with clean findings for several rounds is easy to defend to an insurer; a unit with a run of maintenance notes is the one to budget for.

Where to read more

The chimney inspection page covers the Level 1, and the Level 2 page covers the camera visit. Sale timing is on our property sale page, and the post on pricing a rental's chimneys shows sample totals.

Send the unit list, flags and all, from the contact page; the reply sorts each fireplace into its level with the total in writing.

Units of Your Own to Schedule?

Ellery Chimney Contractors works from San Dimas for owners, boards and managers. Each fireplace gets a dated sheet with photos, and the building gets one summary.

Call (909) 366-3290